{"id":39265,"date":"2017-05-19T08:16:18","date_gmt":"2017-05-19T06:16:18","guid":{"rendered":"https:\/\/blog.wedos.cz\/?p=39265"},"modified":"2021-04-29T10:06:03","modified_gmt":"2021-04-29T08:06:03","slug":"tier-iv-a-napajeni","status":"publish","type":"post","link":"https:\/\/blog.wedos.com\/cs\/tier-iv-a-napajeni","title":{"rendered":"TIER IV a nap\u00e1jen\u00ed"},"content":{"rendered":"\n<p>Ji\u017e d\u0159\u00edve jsme p\u0159edstavili TIER obecn\u011b a tak\u00e9 jak je u TIER d\u016fle\u017eit\u00e1 bezpe\u010dnost. Dnes p\u0159edstav\u00edme v\u0161echno kolem nap\u00e1jen\u00ed.<\/p>\n\n\n\n<!--more-->\n\n\n\n<p>V&nbsp;<a href=\"https:\/\/blog.wedos.cz\/tier-a-certifikace\" target=\"_blank\" rel=\"noopener\">prvn\u00edm d\u00edle seri\u00e1lu<\/a>&nbsp;jsme se v\u011bnovali tomu, co je pojem TIER obecn\u011b.<\/p>\n\n\n\n<p>V&nbsp;<a href=\"https:\/\/blog.wedos.cz\/tier-iv-a-bezpecnost\" target=\"_blank\" rel=\"noopener\">minul\u00e9m d\u00edle seri\u00e1lu<\/a>&nbsp;jsme se v\u011bnovali tomu, jak se u TIER posuzuje bezpe\u010dnost.Dnes probereme nap\u00e1jen\u00ed a v\u0161e kolem nap\u00e1jen\u00ed.&nbsp;V minul\u00e9m d\u00edle seri\u00e1lu jsme se v\u011bnovali tomu, co je pojem TIER obecn\u011b.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Nap\u00e1jen\u00ed a p\u0159\u00edpojky<\/h2>\n\n\n\n<p>Jedn\u00edm z m\u00fdt\u016f o TIER je to, \u017ee datacentrum mus\u00ed m\u00edt 2 nez\u00e1visl\u00e9 zdroje nap\u00e1jen\u00ed &#8211; my\u0161leno 2 p\u0159\u00edpojky. V\u0161e vych\u00e1z\u00ed z neznalost\u00ed. Jak to tedy je? Ka\u017ed\u00e9 datacentrum, kter\u00e9 m\u00e1 spl\u0148ovat stupe\u0148 TIER IV mus\u00ed m\u00edt 2 zcela odd\u011blen\u00e9 nap\u00e1jec\u00ed v\u011btve a\u017e k server\u016fm. Zdroj nap\u00e1jen\u00ed v\u0161ak m\u016f\u017ee b\u00fdt jeden, ale mus\u00ed b\u00fdt dostate\u010dn\u011b z\u00e1lohovan\u00fd. Jak? Motorgener\u00e1tory.<\/p>\n\n\n\n<p>Stejn\u00e9 m\u00fdty jsou ohledn\u011b trafostanic. Datacentrum nemus\u00ed m\u00edt vlastn\u00ed trafostanici nebo dokonce n\u011bkolik trafostanic. M\u016f\u017ee a nemus\u00ed. Pokud m\u00e1te p\u0159\u00edkony do cca 630 A, tak m\u016f\u017eete vyu\u017e\u00edt trafostanice od distributora elekt\u0159iny a odeb\u00edrat elekt\u0159inu v n\u00edzk\u00e9m nap\u011bt\u00ed, ale m\u016f\u017eete si postavit vlastn\u00ed trafostanici a vyu\u017e\u00edvat p\u0159\u00edpojku vysok\u00e9ho nap\u011bt\u00ed. To je sp\u00ed\u0161e takov\u00e9 obchodn\u00ed rozhodnut\u00ed. P\u0159i v\u011bt\u0161\u00edch odb\u011brech jste v\u011bt\u0161inou donuceni si po\u0159\u00eddit vlastn\u00ed trafostanici.&nbsp;<br>Podstatn\u00e9 je to, \u017ee pokud m\u00e1te trafostanici, tak mus\u00edte zajistit jej\u00ed bezpe\u010dnost a kdy\u017e je n\u011bjak<strong>&nbsp;na prvn\u00ed pohled p\u0159\u00edstupn\u00e1 a otev\u0159ete ji z ulice pomoc\u00ed elektrik\u00e1\u0159sk\u00e9 &#8222;kli\u010dky&#8220;, tak v\u011b\u0159te, \u017ee tohle nen\u00ed ta spr\u00e1vn\u00e1 bezpe\u010dnost. Kdy\u017e m\u00e1te v\u00edce trafostanic, tak berte v \u00favahu, \u017ee je nem\u016f\u017eete &#8222;naskl\u00e1dat&#8220; vedle sebe<\/strong>, proto\u017ee pokud dojde k probl\u00e9m\u016fm na jedn\u00e9 &#8211; nap\u0159\u00edklad po\u017e\u00e1r, tak si m\u016f\u017eete b\u00fdt jist\u00ed, \u017ee to zas\u00e1hne i tu sousedn\u00ed. Nem\u016f\u017eete \u0159\u00edkat, \u017ee to je v betonov\u00e9m obalu, kter\u00fd neho\u0159\u00ed. Kdo vid\u011bl ho\u0159et trafostanici, tak potvrd\u00ed, \u017ee tam bude ho\u0159et v\u0161e okolo a nav\u00edc p\u0159i ha\u0161en\u00ed po\u017e\u00e1ru automaticky zas\u00e1hnete i tu druhou. Stejn\u011b tak p\u0159i n\u00e1sledn\u00fdch oprav\u00e1ch budete muset zas\u00e1hnout do t\u00e9 druh\u00e9&#8230;<\/p>\n\n\n\n<p><strong>Nejhor\u0161\u00ed mo\u017en\u00e1 kombinace je, kdy\u017e si d\u00e1te trafostanice vedle sebe a vedle nich d\u00e1te motorgener\u00e1tory, kter\u00e9 jsou tak\u00e9 vedle sebe. Takov\u00e9 datacentrum nikdy TIER IV splnit nem\u016f\u017ee.&nbsp;<\/strong>Sta\u010d\u00ed jeden po\u017e\u00e1r \u010dehokoliv v t\u00e9to soustav\u011b a cel\u00e9 datacentrum je okam\u017eit\u011b bez proudu. I kdyby to nesho\u0159elo samo o sob\u011b (a v\u011b\u0159te tomu, \u017ee to tak nejsp\u00ed\u0161e bude), tak v\u00e1m to &#8222;pokrop\u00ed&#8220; hasi\u010di. Proto je pot\u0159eba m\u00edt v\u0161e odd\u011blen\u00e9 a dostate\u010dn\u011b daleko od sebe. &nbsp;Ide\u00e1ln\u011b je to, kdy\u017e m\u00e1te v\u0161e protipo\u017e\u00e1rn\u011b odd\u011blen\u00e9 jako samostatn\u00e9 protipo\u017e\u00e1rn\u00ed \u00faseky s dostate\u010dnou protipo\u017e\u00e1rn\u00ed odolnost\u00ed a z\u00e1rove\u0148 tak, \u017ee zdroje nap\u00e1jen\u00ed jsou ka\u017ed\u00e9 z jin\u00e9 strany budovy (a vch\u00e1zej\u00ed do budovy jinou trasou).&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Jak to budeme m\u00edt my?<\/h3>\n\n\n\n<p>St\u00e1vaj\u00edc\u00ed datacentrum bude m\u00edt 2 zdroje nap\u00e1jen\u00ed. Jeden zdroj bude ze s\u00edt\u011b n\u00edzk\u00e9ho nap\u011bt\u00ed e.ON a druh\u00fd ze s\u00edt\u011b vysok\u00e9ho nap\u011bt\u00ed, kter\u00fd projde na\u0161\u00ed vlastn\u00ed trafostanic\u00ed (kter\u00e1 bude na smy\u010dce kabel\u016f vysok\u00e9ho nap\u011bt\u00ed). Ka\u017ed\u00e1 nap\u00e1jec\u00ed v\u011btev mus\u00ed b\u00fdt na 100% kapacity datacentra a z\u00e1rove\u0148 bude z\u00e1lohov\u00e1na pomoc\u00ed motorgener\u00e1toru (na ka\u017edou v\u011btev bude jeden), p\u0159i\u010dem\u017e ka\u017ed\u00fd motorgener\u00e1tor mus\u00ed b\u00fdt schopen zajistit 100% provozu datacentra. Pro TIER IV se z hodnot ud\u00e1van\u00fdch v\u00fdrobcem &#8211; Prime (maxim\u00e1ln\u00ed v\u00fdkon b\u011bhem neomezen\u00e9ho \u010dasu, ale s variabiln\u00ed z\u00e1t\u011b\u017e\u00ed) &#8211; sm\u00ed pou\u017e\u00edt pouze 70% kapacity. Tak\u017ee ka\u017ed\u00fd gener\u00e1tor m\u00e1 je\u0161t\u011b des\u00edtky procent rezervu.<\/p>\n\n\n\n<p>Nov\u00e9 datacentrum bude p\u0159ipojen\u00e9 do trafostanice e.ON, kter\u00e1 je na sousedn\u00edm pozemku, cca 1 metr od na\u0161eho plotu. Do trafostanice je p\u0159ivedena smy\u010dka vysok\u00e9ho nap\u011bt\u00ed s\u00edt\u011b e.ON, kter\u00e1 vede do r\u016fzn\u00fdch lokalit. Do t\u00e9to trafostanice &#8211; na stejnou svorkovnici, je p\u0159ipojena tak\u00e9 vodn\u00ed elektr\u00e1rna, kter\u00e1 je schopna zajistit nap\u00e1jen\u00ed 100% kapacity na\u0161eho datacentra. Uvnit\u0159 nov\u00e9ho datacentra budou um\u00edst\u011bny 3 motorgener\u00e1tory, p\u0159i\u010dem\u017e ka\u017ed\u00fd bude schopen zajistit 100% nap\u00e1jen\u00ed datacentra.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">V\u0161e m\u00e1me jinak<\/h3>\n\n\n\n<p>Po d\u016fkladn\u00e9m zva\u017eov\u00e1n\u00ed a hodnocen\u00ed jsem se rozhodli pro zcela samostatn\u00e9 motorgener\u00e1tory, kter\u00e9 nebudou nijak p\u00e1rovan\u00e9 a nijak synchronizovan\u00e9, abychom p\u0159ede\u0161li jak\u00fdmkoliv mo\u017en\u00fdm technick\u00fdm probl\u00e9m\u016fm. V\u0161e bude fungovat pln\u011b automaticky p\u0159es ATS (automatic transfer switch), co\u017e je &#8222;jednoduch\u00fd&#8220; p\u0159ep\u00edna\u010d nap\u00e1jen\u00ed, kter\u00fd um\u00ed jen dv\u011b polohy. Um\u00ed bu\u010f dod\u00e1vat nap\u00e1jen\u00ed z prim\u00e1rn\u00edho zdroje elekt\u0159iny NEBO ze z\u00e1lo\u017en\u00edho. Nikdy nic v\u00edc. Pokud nejde prim\u00e1rn\u00ed, tak se p\u0159epne na z\u00e1lo\u017en\u00ed. Pokud nab\u011bhne zp\u011bt prim\u00e1rn\u00ed, tak se p\u0159epne zp\u011bt na prim\u00e1rn\u00ed.&nbsp;<\/p>\n\n\n\n<p>Nepou\u017e\u00edv\u00e1me a nepl\u00e1nujeme pou\u017e\u00edvat jak\u00e9koliv chytr\u00e9 krabi\u010dky a na n\u011b nav\u00e1zan\u00e9 styka\u010de. Podle r\u016fzn\u00fdch studi\u00ed jsou styka\u010de 15-20x poruchov\u011bj\u0161\u00ed, ne\u017e n\u00e1mi pou\u017e\u00edvan\u00e9 ATS, kter\u00e9 maj\u00ed p\u0159edpokl\u00e1danou dobu \u017eivotnosti (\u010di pr\u016fm\u011brnou dobu mezi poruchami) p\u0159es 100 let. Stejn\u011b tak n\u00e1mi navr\u017een\u00e9 ATS maj\u00ed v\u00fdrazn\u011b vy\u0161\u0161\u00ed po\u010dty p\u0159ep\u00ednac\u00edch cykl\u016f bez poruchy, ne\u017e styka\u010de. Na\u0161e ATS maj\u00ed minim\u00e1ln\u00ed p\u0159edpokl\u00e1dan\u00fd po\u010det cykl\u016f bez poruchy 6.000 p\u0159epnut\u00ed. P\u0159edstavte si tedy, \u017ee 100 let bychom nem\u011bli \u010dekat poruchu, respektive minim\u00e1ln\u011b 6.000 kr\u00e1t m\u016f\u017ee doj\u00edt k v\u00fdpadku nap\u00e1jen\u00ed (a n\u00e1sledn\u00e9mu p\u0159epnut\u00ed ATS na z\u00e1lo\u017en\u00ed zdroj), ne\u017e by mohla nastat porucha. U styka\u010d\u016f jsou po\u010dty v\u00fdrazn\u011b ni\u017e\u0161\u00ed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Co je tedy v\u00fdsledkem?<\/h3>\n\n\n\n<p><strong>V ka\u017ed\u00e9m z datacenter se mohou porouchat (nebo by bylo mo\u017en\u00e9 servisovat) sou\u010dasn\u011b a\u017e 3 zdroje nap\u00e1jen\u00ed a datacentrum bude m\u00edt neust\u00e1le 100% elekt\u0159iny pro provoz! Nap\u00e1jen\u00ed tedy nen\u00ed jen ji\u0161t\u011bn\u00e9 nebo ji\u0161t\u011bn\u00e9 dvakr\u00e1t, ale dokonce t\u0159ikr\u00e1t. Je to jedna z nejkriti\u010dt\u011bj\u0161\u00edch z\u00e1le\u017eitost\u00ed IT provozu a tak se na tohle velmi db\u00e1.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vodn\u00ed elektr\u00e1rna<\/h3>\n\n\n\n<p>R\u00e1di bychom tak\u00e9 uvedli, \u017ee na\u0161e datacentrum bude nejen mimo\u0159\u00e1dn\u011b ekologick\u00e9, proto\u017ee budeme vyu\u017e\u00edvat velmi \u00fasporn\u00e9 olejov\u00e9 chlazen\u00ed a z\u00e1rove\u0148 odpadn\u00ed teplo vyu\u017eije m\u00edstn\u00ed plov\u00e1rna, ale na\u0161e datacentrum bude prim\u00e1rn\u011b nap\u00e1jen\u00e9 z vodn\u00ed elektr\u00e1rny.&nbsp;<br>Servery budou d\u00edky olejov\u00e9mu chlazen\u00ed o des\u00edtky procent \u00fasporn\u011bj\u0161\u00ed (nemusej\u00ed m\u00edt ventil\u00e1tory je\u017e spot\u0159ebuj\u00ed cca 30% energie). Z\u00e1rove\u0148 nebudeme pot\u0159ebovat \u017e\u00e1dn\u00e9 velk\u00e9 ventil\u00e1tory na chlazen\u00ed a ani klimatizace. Prost\u011b \u00fasporn\u00fd provoz s vyu\u017eit\u00edm odpadn\u00edho tepla. Pokud by n\u011bkdo vyhro\u017eoval t\u00edm, \u017ee tam m\u00e1me olej, tak n\u00e1\u0161 monolitick\u00fd betonov\u00fd objekt je koncipov\u00e1n jako z\u00e1chytn\u00e1 vana a kdyby n\u00e1m vytekl ve\u0161ker\u00fd olej, kter\u00fd v budov\u011b bude, tak budeme m\u00edt v z\u00e1chytn\u00e9 van\u011b necel\u00fdch 15 centimetr\u016f a p\u0159itom vana je p\u0159es 50 centimetr\u016f. Ale na toto t\u00e9ma nap\u00ed\u0161eme zase n\u011bkdy v\u00edce a detailn\u011bji p\u0159\u00ed\u0161t\u011b..&nbsp;<br><strong>V\u00edte o n\u011bjak\u00e9m zelen\u011bj\u0161\u00edm a ekologi\u010dt\u011bj\u0161\u00edm projektu?<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Nap\u00e1jen\u00ed uvnit\u0159 budovy<\/h2>\n\n\n\n<p>Samostatnou kapitolou jsou rozvody nap\u00e1jen\u00ed uvnit\u0159 budovy. &nbsp;Co je podstatn\u00e9? Rozvody nap\u00e1jen\u00ed musej\u00ed b\u00fdt nachystan\u00e9 tak, \u017ee v\u0161echny prvky musej\u00ed b\u00fdt nap\u00e1jen\u00e9 ze 2 nap\u00e1jec\u00edch v\u011btv\u00ed sou\u010dasn\u011b. Ka\u017ed\u00fd server tedy mus\u00ed m\u00edt zaji\u0161t\u011bn\u00e9 nap\u00e1jen\u00ed ze dvou v\u011btv\u00ed (v na\u0161ich sch\u00e9matech v\u011btev A a v\u011btev B) sou\u010dasn\u011b a ka\u017ed\u00e1 v\u011btev mus\u00ed b\u00fdt schopna zajistit dodat v\u017edy a za jak\u00e9koliv okolnosti 100% nap\u00e1jen\u00ed.&nbsp;<\/p>\n\n\n\n<p><strong>Mimo\u0159\u00e1dn\u011b d\u016fle\u017eit\u00e9 je to, aby v\u0161echny \u010d\u00e1sti a v\u0161echny prvky byly odd\u011blen\u00e9 a nikde se nesm\u00ed v\u011btev A potkat nebo k\u0159\u00ed\u017eit s v\u011btv\u00ed B. V\u0161e mus\u00ed b\u00fdt odd\u011blen\u00e9 nejen n\u011bjakou vzd\u00e1lenost\u00ed, ale p\u0159edev\u0161\u00edm fyzicky, aby n\u011bjak\u00e1 hav\u00e1rie jedn\u00e9 v\u011btve neohrozila druhou v\u011btev. Stejn\u011b tak mus\u00ed b\u00fdt odd\u011blen\u00e9 v\u0161e protipo\u017e\u00e1rn\u011b.&nbsp;<\/strong><\/p>\n\n\n\n<p>P\u0159edstavte si tedy to, \u017ee mus\u00edte do ka\u017ed\u00e9ho racku dostat 2 nap\u00e1jen\u00ed, ale tyto 2 kabely se v\u00e1m nesm\u00ed nikde potkat, nikde potkat v jednom prostoru, nesm\u011bj\u00ed m\u00edt soub\u011bh v jednom prostoru a nesm\u011bj\u00ed se ani k\u0159\u00ed\u017eit. Tohle je sranda, &nbsp;kterou si zkuste nakreslit a promyslet jak to chcete ud\u011blat. Na tomhle skon\u010d\u00ed v\u011bt\u0161ina datacenter, proto\u017ee nejsou fyzicky postavena tak, aby tohle bylo mo\u017en\u00e9 realizovat. V podstat\u011b \u017e\u00e1dn\u00e9 takov\u00e9 datacentrum na tohle nen\u00ed v \u010cR asi p\u0159ipraven\u00e9 a tak TIER IV nem\u016f\u017ee nikdo z\u00edskat. I tohle m\u016f\u017ee b\u00fdt jeden z d\u016fvod\u016f, pro\u010d nen\u00ed \u017e\u00e1dn\u00e9 datacentrum TIER IV v \u010cR, ani SR, ani v Polsku, ani v Ma\u010farsku, ani v Rakousku a ani v N\u011bmecku&#8230;<\/p>\n\n\n\n<p><strong>Naprosto nep\u0159\u00edpustn\u00e9 je to, \u017ee nat\u00e1hnete ob\u011b nap\u00e1jec\u00ed v\u011btve v jednom prostoru sou\u010dasn\u011b &#8211; nap\u0159\u00edklad pod zdvojenou podlahou.&nbsp;<\/strong>Tohle je z hlediska TIER IV naprosto nep\u0159\u00edpustn\u00e9. Stejn\u011b tak jako n\u011bjak\u00e9 k\u0159\u00ed\u017een\u00ed tras apod.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Jak to ud\u011bl\u00e1me my?&nbsp;<\/h3>\n\n\n\n<p>Jedna nap\u00e1jec\u00ed v\u011btev bude um\u00edst\u011bna pod zdvojenou podlahou, kter\u00e1 je neho\u0159lav\u00e1 a postavena tak, aby splnila p\u0159\u00edslu\u0161nou protipo\u017e\u00e1rn\u00ed odolnost.<\/p>\n\n\n\n<p>Druh\u00e1 nap\u00e1jec\u00ed v\u011btev bude um\u00edst\u011bna pod stropem, zakryta s\u00e1drokartonov\u00fdm podhledem s p\u0159\u00edslu\u0161nou protipo\u017e\u00e1rn\u00ed odolnost\u00ed.&nbsp;<\/p>\n\n\n\n<p>P\u0159edt\u00edm, ne\u017e se ob\u011b v\u011btve dostanou do podlahy, respektive do podhledu, tak se nikde p\u0159edt\u00edm nek\u0159\u00ed\u017e\u00ed, v\u0161e je odd\u011blen\u00e9, izolovan\u00e9 a to jak fyzicky, tak i protipo\u017e\u00e1rn\u011b.<\/p>\n\n\n\n<p>Ob\u011b nap\u00e1jen\u00ed se potkaj\u00ed a\u017e v racku, ale ani tam se nebudou k\u0159\u00ed\u017eit. Jedna p\u0159ijde otvorem v podlaze a &nbsp;bude na jedn\u00e9 stran\u011b racku (nebo chlad\u00edc\u00ed vany v nov\u00e9m datacentru). Druh\u00e1 v\u011btev p\u0159ijde otvorem ve strop\u011b a do racku p\u0159ijde vrchem a bude na druh\u00e9 stran\u011b racku (respektive chlad\u00edc\u00ed vany v nov\u00e9m datacentru).<\/p>\n\n\n\n<p><strong>Stejn\u00e1 pravidla plat\u00ed i pro dal\u0161\u00ed z\u00e1le\u017eitosti datacentra &#8211; chlazen\u00ed (a nap\u00e1jen\u00ed chlazen\u00ed) a konektivitu uvnit\u0159 datacentra<\/strong>&nbsp;(o konektivit\u011b vn\u011b datacentra jsme psali ji\u017e minule).&nbsp;Nikde nesm\u00edte m\u00edt \u017e\u00e1dn\u00e9 k\u0159\u00ed\u017een\u00ed, \u017e\u00e1dn\u00fd soub\u011bh, nic v jednom prostoru. I tam bude n\u00e1\u0161 p\u0159\u00edstup podobn\u00fd jako u nap\u00e1jen\u00ed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Co dal\u0161\u00edho je podstatn\u00e9ho s nap\u00e1jen\u00edm?<\/h3>\n\n\n\n<p>V\u0161echny \u010d\u00e1sti nap\u00e1jen\u00ed musej\u00ed b\u00fdt pln\u011b servisovateln\u00e9 a to v\u017edy tak, aby st\u00e1le fungovalo 100% nap\u00e1jen\u00ed a st\u00e1le mus\u00edte zajistiti, aby fungovaly ob\u011b nap\u00e1jec\u00ed v\u011btve sou\u010dasn\u011b! Nen\u00ed to tak jednoduch\u00e9, kdy\u017e si p\u0159edstav\u00edte, \u017ee mus\u00edte b\u00fdt schopni servisovat motorgener\u00e1tory, UPSky, rozvad\u011b\u010de, ve\u0161kerou kabel\u00e1\u017e a v\u0161echny ji\u017e zmi\u0148ovan\u00e9 p\u0159ep\u00edna\u010de (ATS). Nen\u00ed to jen tak. Tak\u00e9 n\u00e1m to dalo hodn\u011b pr\u00e1ce, abychom to vymysleli.&nbsp;<\/p>\n\n\n\n<p>Z hlediska servisu nejde jen o n\u011bjak\u00e9 pravideln\u00e9 kontroly a revize z hlediska z\u00e1kona, ale jde tak\u00e9 o p\u0159edch\u00e1zen\u00ed chyb\u00e1m a sledov\u00e1n\u00ed a monitorov\u00e1n\u00ed cel\u00e9ho syst\u00e9mu. O kontrole a testov\u00e1n\u00ed bychom mohli ps\u00e1t asi rom\u00e1ny. V\u011b\u0159te tomu, \u017ee u n\u00e1s ka\u017ed\u00fd t\u00fdden kontrolujeme stav rozvod\u016f senzoricky na za\u010d\u00e1tku t\u00fddne a ka\u017ed\u00fd \u010dtvrtek testujeme zda v\u0161e funguje spr\u00e1vn\u011b i provozn\u011b. Ka\u017ed\u00fd \u010dtvrtek testujeme zda n\u00e1m nasko\u010d\u00ed n\u00e1hradn\u00ed zdroj nap\u00e1jen\u00ed. A prvn\u00ed \u010dtvrtek v m\u011bs\u00edci v\u017edy testujeme black-out. Ano, v\u017edy vypneme hlavn\u00ed p\u0159\u00edvod nap\u00e1jen\u00ed a testujeme kompletn\u00ed b\u011bh v\u0161ech syst\u00e9m\u016f. Po cca 30 minut\u00e1ch p\u0159\u00edvod nap\u00e1jen\u00ed nahod\u00edme a sledujeme zda dojde k opa\u010dn\u00e9mu stavu &#8211; p\u0159epnut\u00ed v\u0161ech syst\u00e9m\u016f na elektrickou s\u00ed\u0165. I tohle je jedna z cest jak p\u0159edch\u00e1zet lidsk\u00fdm chyb\u00e1m.&nbsp;<\/p>\n\n\n\n<p>Cel\u00fd syst\u00e9m nap\u00e1jen\u00ed mus\u00ed b\u00fdt schopn\u00fd pln\u011b automatick\u00e9ho provozu. V\u0161e mus\u00ed fungovat samo a reagovat na chyby a poruchy tak, aby nemusel kdokoliv a kdekoliv n\u011bco d\u011blat. &nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Motorgener\u00e1tory<\/h2>\n\n\n\n<p>U motorgener\u00e1tor\u016f se vych\u00e1z\u00ed z mezin\u00e1rodn\u00ed normy ISO&nbsp;Standard 8528-1. Ka\u017ed\u00fd gener\u00e1tor je tak hodnocen ve 3 hodnot\u00e1ch &#8211;&nbsp;Emergency Standby (hodnota maxim\u00e1ln\u00edho v\u00fdkonu je\u017e m\u016f\u017ee zvl\u00e1dnout kr\u00e1tkodob\u011b &#8211; maxim\u00e1ln\u011b 200 hodin ro\u010dn\u011b), Prime (maxim\u00e1ln\u00ed v\u00fdkon b\u011bhem neomezen\u00e9ho \u010dasu, ale s variabiln\u00ed z\u00e1t\u011b\u017e\u00ed) a Continuous (maxim\u00e1ln\u00ed v\u00fdkon bez omezen\u00ed \u010dasu s trvalou z\u00e1t\u011b\u017e\u00ed).<\/p>\n\n\n\n<p>Jak\u00fd gener\u00e1tor lze pou\u017e\u00edt a s jakou hodnotou? Z\u00e1le\u017e\u00ed na v\u00fdrobci. Continuous bez omezen\u00ed. &nbsp;Prime &#8211; jen 70% kapacity ud\u00e1van\u00e9 v\u00fdrobcem. Mus\u00edte tedy pou\u017e\u00edt v\u00fdrazn\u011b siln\u011bj\u0161\u00ed motorgener\u00e1tor, ne\u017e pot\u0159ebujete pro provoz. Po\u010d\u00edt\u00e1 se s t\u00edm, \u017ee tam bude dostate\u010dn\u00e1 rezerva pro jak\u00fdkoliv probl\u00e9m.<\/p>\n\n\n\n<p>Motorgener\u00e1tory pro TIER III nebo TIER IV musej\u00ed spl\u0148ovat n\u011bkolik krit\u00e9ri\u00ed. Ne\u010dekejte \u017e\u00e1dn\u00e9 nesmysln\u00e9 hodnoty jak dlouho musej\u00ed motorgener\u00e1tory fungovat. Je to pom\u011brn\u011b jednoduch\u00e9. Motorgener\u00e1tory musej\u00ed:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>b\u00fdt ur\u010den\u00e9 pro nep\u0159etr\u017eit\u00fd provoz, v\u011b\u0159te tomu, \u017ee to nen\u00ed zcela b\u011b\u017en\u00e9,<\/li><li>musej\u00ed m\u00edt z\u00e1sobu na 12 hodin nep\u0159etr\u017eit\u00e9ho provozu na celou kapacitu datacentra,<\/li><li>op\u011bt musej\u00ed b\u00fdt dostate\u010dn\u011b fyzicky odd\u011blen\u00e9, aby byla zaji\u0161t\u011bna fyzick\u00e1 bezpe\u010dnost (gener\u00e1tory musej\u00ed b\u00fdt dostate\u010dn\u011b chr\u00e1n\u011bn\u00e9 a plot moc nesta\u010d\u00ed)<\/li><li>protipo\u017e\u00e1rn\u00ed bezpe\u010dnost a je tak t\u0159eba nep\u0159\u00edpustn\u00e9, aby byly motorgener\u00e1tory vedle sebe nebo n\u011bkolik metr\u016f od sebe bez jak\u00e9hokoliv protipo\u017e\u00e1rn\u00edho odd\u011blen\u00ed a p\u0159ep\u00e1\u017eek s dostate\u010dnou protipo\u017e\u00e1rn\u00ed odolnost\u00ed.&nbsp;<br><strong>To je zcela b\u011b\u017en\u00e1 chyba a vid\u00edte ji prakticky v\u0161ude, ve v\u0161ech datacenterech.<\/strong><\/li><\/ul>\n\n\n\n<p>Pro jistotu jsme se rozhodli, \u017ee motorgener\u00e1tory budeme m\u00edt ka\u017ed\u00fd od jin\u00e9ho v\u00fdrobce, Je to sice komplikace se servisem, ale je to bezpe\u010dn\u011bj\u0161\u00ed, proto\u017ee n\u00e1s v budoucnu nepotk\u00e1 n\u011bjak\u00e1 skryt\u00e1 s\u00e9riov\u00e1 vada.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">UPS<\/h2>\n\n\n\n<p>UPS mus\u00edte m\u00edt tak\u00e9 dvakr\u00e1t. Jednou na nap\u00e1jec\u00ed v\u011btvi A a jednou na nap\u00e1jec\u00ed v\u011btvi B. Ka\u017ed\u00e1 nap\u00e1jec\u00ed v\u011btev mus\u00ed b\u00fdt schopna zajistit 100% nap\u00e1jen\u00ed cel\u00e9ho datacentra. Z\u00e1rove\u0148 mus\u00edte b\u00fdt schopni UPS kdykoliv servisovat a nebo celou vym\u011bnit a p\u0159itom z\u00e1rove\u0148 zajistit 100% nap\u00e1jen\u00ed na obou nap\u00e1jec\u00edch v\u011btv\u00edch sou\u010dasn\u011b.&nbsp;<strong>V takov\u00e9m p\u0159\u00edpad\u011b dosp\u011bjete k tomu, \u017ee nelze nap\u0159\u00edklad pou\u017e\u00edt modul\u00e1rn\u00ed UPS<\/strong>, kter\u00e9 mohou fungovat v re\u017eimu N+1. Tam toti\u017e nejde ud\u011blat v\u00fdm\u011bnu bez odst\u00e1vky cel\u00e9 nap\u00e1jec\u00ed v\u011btve. Mus\u00edte m\u00edt N+1 UPS na ka\u017ed\u00e9 nap\u00e1jec\u00ed v\u011btvi fyzicky, abyste byli schopni cokoliv servisovat nebo vym\u011bnit.&nbsp;<\/p>\n\n\n\n<p><strong>Jako samoz\u0159ejmost se bere to, \u017ee UPS pro jednotliv\u00e9 v\u011btv\u011b jsou zcela fyzicky odd\u011blen\u00e9 &nbsp;v samostatn\u00fdch prostor\u00e1ch a z\u00e1rove\u0148 baterie jsou v samostatn\u00fdch prostor\u00e1ch. Kabel\u00e1\u017e pro r\u016fzn\u00e9 nap\u00e1jec\u00ed v\u011btv\u011b se nesm\u00ed k\u0159\u00ed\u017eit, nesm\u00ed b\u00fdt soub\u011bh a nesm\u00ed b\u00fdt v jednom prostoru.&nbsp;<\/strong><\/p>\n\n\n\n<p>Nutn\u00e9 je p\u0159ipomenout, \u017ee u TIER IV mus\u00edte zajistit bezv\u00fdpadkov\u00e9 chlazen\u00ed a tak i chlazen\u00ed mus\u00ed pou\u017e\u00edvat UPS. M\u00e1te dv\u011b mo\u017enosti &#8211; bu\u010f pou\u017eijete UPS, kter\u00e9 jsou pro servery NEBO pro chlazen\u00ed d\u00e1te vlastn\u00ed UPS. My tohle druh\u00e9 \u0159e\u0161en\u00ed pova\u017eujeme za lep\u0161\u00ed a bezpe\u010dn\u011bj\u0161\u00ed a proto na\u0161e chlazen\u00ed v ka\u017ed\u00e9m datacentru bude m\u00edt 2 samostatn\u00e9 UPS, p\u0159i\u010dem\u017e ka\u017ed\u00e1 z t\u011bchto UPS mus\u00ed b\u00fdt schopna zajistit 100% nap\u00e1jen\u00ed pro 100% chlazen\u00ed cel\u00e9ho datacentra.<\/p>\n\n\n\n<p>Samostatn\u00e9 UPS jsou pro kancel\u00e1\u0159e. Op\u011bt je m\u00e1me odd\u011blen\u00e9 od UPS, kter\u00e9 nap\u00e1jej\u00ed servery.<\/p>\n\n\n\n<p>V\u0161echny UPS musej\u00ed b\u00fdt koncipovan\u00e9 na minim\u00e1ln\u00ed dobu 15 minut z\u00e1lohy na 100% kapacity datacentra. Pokud vezmete v \u00favahu, \u017ee tedy v\u0161e m\u00e1te zdvojen\u00e9, tak m\u00e1te zaji\u0161t\u011bn\u00fdch 30 minut p\u0159es UPS. V na\u0161em p\u0159\u00edpad\u011b to bude je\u0161t\u011b v\u00edce, proto\u017ee budeme m\u00edt UPS v re\u017eimu 2N + 1. Budeme m\u00edt v\u017edy jednu UPS na ka\u017ed\u00e9 v\u011btvi nav\u00edc a bude slou\u017eit jako z\u00e1loha pro p\u0159\u00edpad poruchy jin\u00e9 UPS.<\/p>\n\n\n\n<p>Stejn\u011b jako u motorgener\u00e1tor\u016f, tak i u UPS jsme se pro jistotu rozhodli, \u017ee UPS budou na jednotliv\u00fdch v\u011btv\u00edch od r\u016fzn\u00fdch v\u00fdrobc\u016f a na jednotliv\u00fdch v\u011btv\u00edch je koup\u00edme r\u016fzn\u011b v \u010dase. Je to sice komplikace se servisem, ale je to bezpe\u010dn\u011bj\u0161\u00ed, proto\u017ee n\u00e1s v budoucnu nepotk\u00e1 n\u011bjak\u00e1 skryt\u00e1 s\u00e9riov\u00e1 vada.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IT prvky<\/h2>\n\n\n\n<p>V\u0161echny IT za\u0159\u00edzen\u00ed musej\u00ed m\u00edt du\u00e1ln\u00ed nap\u00e1jen\u00ed (minim\u00e1ln\u011b dva zdroje) nebo mus\u00ed b\u00fdt p\u0159ipojen\u00ed p\u0159es takzvan\u00e9 ATS, kter\u00e9 zajist\u00ed pou\u017eit\u00ed obou nap\u00e1jec\u00edch v\u011btv\u00ed. V tomto p\u0159\u00edpad\u011b se jedn\u00e9 o trochu jin\u00e9 ATS, ne\u017e m\u00e1me my v na\u0161em sch\u00e9matu a bavili jsme se o nich v\u00fd\u0161e. Tyto rackov\u00e9 ATS funguj\u00ed podobn\u011b, ale jsou to &#8222;elektronick\u00e1 za\u0159\u00edzen\u00ed&#8220;, kter\u00e1 sp\u00ednaj\u00ed mal\u00e9 proudy (v\u011bt\u0161inou do 16A). V\u0161e prob\u00edh\u00e1 elektronicky. N\u00e1mi uv\u00e1d\u011bn\u00e9 ATS sp\u00ednaj\u00ed proudy 630 nebo v\u00edc amp\u00e9r) a jsou sp\u00ednan\u00e9 pomoc\u00ed siln\u00fdch elektromotor\u016f. Jen pro \u00faplnost dod\u00e1me, \u017ee p\u0159epnut\u00ed z jednoho zdroje nap\u00e1jen\u00ed na druh\u00fd trv\u00e1 od 10-100 ms a v\u011bt\u0161ina nap\u00e1jec\u00edch zdroj\u016f u server\u016f tak rychl\u00e9 p\u0159epnut\u00ed nepozn\u00e1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Chcete vid\u011bt na\u0161e sch\u00e9ma nap\u00e1jen\u00ed?<\/h2>\n\n\n\n<p>Asi prozrad\u00edme \u00fapln\u011b nejv\u00edce, ale uk\u00e1\u017eeme v\u00e1m na\u0161e sch\u00e9mata nap\u00e1jen\u00ed. Podobn\u00e1 sch\u00e9mata jsou v\u011bt\u0161inou tajn\u00e1 a to vzhledem k tomu, \u017ee obsahuj\u00ed hodn\u011b pr\u00e1ce a pova\u017euj\u00ed se za obchodn\u00ed tajemstv\u00ed. Vzhledem k na\u0161\u00ed otev\u0159enosti v\u00e1m sch\u00e9mata uk\u00e1\u017eeme.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Na co se m\u016f\u017eete t\u011b\u0161it p\u0159\u00ed\u0161t\u011b?<\/h2>\n\n\n\n<p>P\u0159\u00ed\u0161t\u011b si nap\u00ed\u0161eme dal\u0161\u00ed informace a detaily. Prozrad\u00edme i n\u011bjak\u00e9 detaily z na\u0161eho z\u00e1kulis\u00ed. Nakonec se dozv\u00edte i o nej\u010dast\u011bj\u0161\u00edch chyb\u00e1ch nebo o ekonomice provozu takov\u00e9ho datacentra. Ekonomika provozu bude na samostatnou kapitolu.&nbsp;<\/p>\n\n\n\n<p>Vzhledem k tomu, \u017ee n\u00e1s certifikace TIER IV bav\u00ed a bereme j\u00ed jako jednu z nejv\u011bt\u0161\u00edch v\u00fdzev, tak si p\u0159\u00ed\u0161t\u011b detailn\u011b probereme n\u011bkter\u00e9 technick\u00e9 p\u0159edpoklady, kter\u00e9 mus\u00ed TIER IV datacentrum spl\u0148ovat.<\/p>\n\n\n\n<p>Ur\u010dit\u011b se dostane i na re\u00e1ln\u00e9 p\u0159\u00edklady, podle kter\u00fdch pochop\u00edte pro\u010d v \u010cR (a ani jinde ve st\u0159edn\u00ed Evrop\u011b &#8211; v\u010detn\u011b N\u011bmecka, Polska, Ma\u010farska, Slovenska, Rakouska) doposud \u017e\u00e1dn\u00e9 datacentrum certifikaci TIER IV nem\u00e1. Pokud m\u00e1te ot\u00e1zky, tak n\u00e1m pi\u0161te a my m\u016f\u017eeme zohlednit odpov\u011bdi v dal\u0161\u00edch \u010dl\u00e1nc\u00edch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pro\u010d to cel\u00e9 d\u011bl\u00e1me?<\/h2>\n\n\n\n<p>D\u016fvod\u016f je n\u011bkolik. Jsme nejv\u011bt\u0161\u00ed hostingov\u00e1 spole\u010dnost v \u010cR, v na\u0161em datacentru hostujeme nejv\u00edce slu\u017eeb v \u010cR a tak jsme si v\u011bdomi toho, \u017ee mus\u00edme v\u0161e sm\u011b\u0159ovat k maxim\u00e1ln\u00ed spokojenosti na\u0161ich klient\u016f. Kvalita datacentra je pro n\u00e1\u0161 dal\u0161\u00ed r\u016fst a rozvoj jednozna\u010dn\u011b velmi d\u016fle\u017eit\u00fdm faktorem a bez kvalitn\u00edho z\u00e1zem\u00ed to ur\u010dit\u011b nep\u016fjde. )<\/p>\n\n\n\n<p>Proto chceme m\u00edt 2 modern\u00ed datacentra, kter\u00e1 budou spl\u0148ovat ta nejn\u00e1ro\u010dn\u011bj\u0161\u00ed krit\u00e9ria a cel\u00e9 si to chceme nechat takhle certifikovat. Nejdeme cestou toho, \u017ee n\u00e1m n\u011bkdo n\u011bco n\u011bkde n\u011bjak nakresl\u00ed a n\u011bkdo n\u011bkde n\u011bjak rychle postav\u00ed. Jdeme cestou, \u017ee p\u0159\u00edprav\u00e1m v\u011bnujeme obrovsk\u00e9 mno\u017estv\u00ed \u010dasu, chyst\u00e1me to n\u011bkolik let v t\u00fdmu n\u011bkolika lid\u00ed. V\u0161e si na stavb\u011b hl\u00edd\u00e1me a v\u0161e operativn\u011b rozhodujeme. Ve v\u00fdsledku v\u0161echny provozn\u00ed v\u011bci chceme \u0159e\u0161it &#8222;in house&#8220;. M\u00e1me tedy nap\u0159\u00edklad vlastn\u00ed elektrik\u00e1\u0159e (dokonce 2). Tak\u017ee v\u00edme o v\u0161em v na\u0161\u00ed budov\u011b. V\u0161e si dok\u00e1\u017eeme vy\u0159e\u0161it vlastn\u00edmi silami. Co nejrychleji a nejl\u00e9pe.<\/p>\n\n\n\n<p>Ob\u011b datacentra budou navenek p\u016fsobit jako jedno, ale ve skute\u010dnosti p\u016fjde o 2 samostatn\u00e9 budovy, kter\u00e9 budou schopny fungovat zcela odd\u011blen\u011b nebo se n\u011bjak vz\u00e1jemn\u011b v provozu dopl\u0148ovat. P\u016fjde o takov\u00fd RAID datacenter.&nbsp;<\/p>\n\n\n\n<p>Ano, ekonomicky nic z toho ned\u00e1v\u00e1 smysl, ale my d\u011bl\u00e1me v\u0161e pro maxim\u00e1ln\u00ed spokojenost na\u0161ich klient\u016f. To je prvo\u0159ad\u00fd c\u00edl. D\u011bl\u00e1me to, proto\u017ee n\u00e1s to bav\u00ed. Ekonomick\u00e1 str\u00e1nka je druhotnou z\u00e1le\u017eitost\u00ed a jak \u0159\u00edk\u00e1me: &#8222;Kdy\u017e budou klienti spokojeni, tak i ty zisky p\u0159ijdou&#8220;. Jsme siln\u00e1 spole\u010dnost, kter\u00e1 jede bez \u00fav\u011br\u016f a z\u00e1vazk\u016f. Vlastn\u00edme datacentrum, infrastrukturu a nemus\u00edme se &#8222;zpov\u00eddat n\u011bjak\u00e9 bance&#8220;. Stav\u00edme druh\u00e9 datacentrum za des\u00edtky milion\u016f korun a to op\u011bt bez jak\u00e9koliv pomoci t\u0159et\u00edch stran. Mo\u017en\u00e1 by \u0161lo si pen\u00edze ponechat a koupit si za n\u011b n\u011bco &#8222;pro radost&#8220;, ale n\u00e1s bav\u00ed tohle a n\u00e1s bav\u00ed spokojen\u00ed klienti.&nbsp;<\/p>\n\n\n\n<p><strong>Pl\u00e1novan\u00e9 certifikace by m\u011bly b\u00fdt z\u00e1rukou pro na\u0161e klienty, \u017ee jejich data jsou na tom nejlep\u0161\u00edm m\u00edst\u011b a \u017ee je o n\u011b dob\u0159e postar\u00e1no.<\/strong><\/p>\n\n\n\n<p>Bu\u010fte s n\u00e1mi a sledujte jak se n\u00e1m na\u0161e pl\u00e1ny da\u0159\u00ed.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ji\u017e d\u0159\u00edve jsme p\u0159edstavili TIER obecn\u011b a tak\u00e9 jak je u TIER d\u016fle\u017eit\u00e1 bezpe\u010dnost. Dnes p\u0159edstav\u00edme v\u0161echno kolem nap\u00e1jen\u00ed.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[64,3],"tags":[66],"class_list":["post-39265","post","type-post","status-publish","format-standard","hentry","category-datacentra","category-spolecnost","tag-tier"],"_links":{"self":[{"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/posts\/39265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/comments?post=39265"}],"version-history":[{"count":2,"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/posts\/39265\/revisions"}],"predecessor-version":[{"id":40023,"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/posts\/39265\/revisions\/40023"}],"wp:attachment":[{"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/media?parent=39265"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/categories?post=39265"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wedos.com\/cs\/wp-json\/wp\/v2\/tags?post=39265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}